The PATON StandardCUT-70-400V inverter plasma cutter is designed for manual cutting of metals and alloys up to 25 mm thick with a plasma arc in a stream of compressed air. The plasma cutter is lightweight and easy to set up, thanks to its infinitely variable current control, which allows for precise cutting without metal deformation, both in sheet metal and in curved cutting. It is equipped with a pneumatic system with two valves for soft arc ignition with reduced metal spatter, which significantly increases the life of plasma torch consumables. The torch protection system avoids ignition at insufficient air pressure.
PATON 3m Earth Return, 10mm²
Genuine Binzel ABIPLAS CUT 70 4m Torch for use with PATON Plasma Machines
PATON Quick Gas Connector
PATON 1 Year Warranty
Straight answers to the questions people ask most when choosing and using three-phase plasma cutters.
A three-phase connection can provide much more power to the machine, so three-phase plasma cutters can reach higher outputs, cut thicker material and work for longer. The power draw is also spread across three conductors, which is smoother and puts less strain on the installation.They are the usual choice for industrial fabrication, heavy repair and production cutting.
In practice, yes for most buyers. The UK three-phase supply is commonly called 400 V or 415 V depending on the era and the label, and machines of this type are designed to run on it.Always check the machine's data plate for its accepted voltage range, and confirm your premises supply falls within it before connecting.
No. A three-phase machine needs a three-phase supply, and the right plug, socket and protection for its input current. A normal single-phase socket cannot power it.If you do not have three-phase, you can look at a single-phase machine instead. Do not attempt to modify the supply yourself; have a qualified electrician install or inspect it.
It can, depending on the design of the machine. Some machines are unaffected by the order in which the three phases are connected, while others, especially those with a cooling fan or built-in air compressor, may run backwards or report a fault if the rotation is wrong.The manual and data plate for your machine state whether rotation matters. If a fan runs the wrong way or a fault shows after connection, isolate the machine and have a qualified electrician check and correct the wiring rather than guessing.