    Beta e90 PFA with PFU PAPR Parts FAQs

    Straight answers on choosing, fitting and looking after the spare parts for a welding helmet with a battery-powered air-purifying blower.

    Which parts of a powered air-purifying welding helmet wear out or need replacing?icon-minus-redicon-plus-red

    The main items are the particle filters and any pre-filters, the rechargeable battery, the breathing hose, the lenses (the outer cover lens and the filter lens) and the headband and fitting parts. Filters and batteries are the ones replaced most often, which is why HSE advises keeping spare batteries and filters to hand as part of an RPE programme.

    The blower unit and helmet shell usually last far longer. Check your manual for which parts are intended to be replaced by the user.

    How do I know when to change a particle filter?icon-minus-redicon-plus-red

    Change a filter that is damaged or visibly contaminated, or that has become harder to breathe through or restricts the airflow. This can happen quickly in very dusty conditions. For filters used with fan-assisted respirators, the manufacturer sets the change interval, so follow the manual.

    Many blowers also have an airflow or filter warning; if yours does, take it seriously and stop welding to fix the cause. Never use a filter past its shelf-life date, and it helps to mark the date a filter was fitted.

    When should I replace the battery, and what should I watch for?icon-minus-redicon-plus-red

    Inspect the battery before use and do not use it if it is damaged, leaking or swollen. Use only the battery type the manufacturer names for your blower, and the charger it specifies, because the battery has to give the airflow the respirator needs.

    Replace it when airflow keeps falling quickly, run time becomes much shorter than it was, or it fails the airflow check. Store and charge it as the manual says, avoiding high heat, and ask the maker about disposal.

    How should I look after the breathing hose?icon-minus-redicon-plus-red

    Inspect the hose and its connections before each use for cracks, kinks, splits or loose fittings, because a damaged hose can leak air or restrict flow. Keep it away from sparks, spatter and sharp edges, and route it so it does not snag.

    Wipe it clean as the manufacturer advises, and let it dry before storing it. Do not use solvents unless the manual allows them. Replace a damaged hose rather than repairing it with tape.