Beta e90 PFA with PFU PAPR Parts FAQs
Straight answers on choosing, fitting and looking after the spare parts for a welding helmet with a battery-powered air-purifying blower.
How do I know when to change a particle filter?

Change a filter that is damaged or visibly contaminated, or that has become harder to breathe through or restricts the airflow. This can happen quickly in very dusty conditions. For filters used with fan-assisted respirators, the manufacturer sets the change interval, so follow the manual.
Many blowers also have an airflow or filter warning; if yours does, take it seriously and stop welding to fix the cause. Never use a filter past its shelf-life date, and it helps to mark the date a filter was fitted.
How do I find the right spare part for my helmet and blower?

Use the manual, the data plate on the blower and the markings on the old part. Helmets, blowers, hoses and filters are normally designed as a matched system, and one set of parts may not suit another even if it looks similar.
Note the full part number or marking from the old part and compare it with the new one. Do not rely on size alone. Parts for different helmet versions in the same range can differ, so if you are unsure, our team can help you match the part to your equipment.
How often should I check the battery and airflow?

Check the battery condition and airflow before every use, as the manufacturer instructs. Trade guidance for powered respirators also suggests checking the airflow level or battery status again during long shifts, for example after four hours and then every two hours, though the interval depends on your manufacturer and risk assessment.
If the airflow drops or the low-flow warning sounds, leave the fume area, following your RPE procedure, and change or recharge the battery in clean air. Charge the battery as the maker describes.
When should I replace the battery, and what should I watch for?

Inspect the battery before use and do not use it if it is damaged, leaking or swollen. Use only the battery type the manufacturer names for your blower, and the charger it specifies, because the battery has to give the airflow the respirator needs.
Replace it when airflow keeps falling quickly, run time becomes much shorter than it was, or it fails the airflow check. Store and charge it as the manual says, avoiding high heat, and ask the maker about disposal.